DeviceNetACON-C/CGPCON-C/CG/CA/CFASCON-CAOperation Manual, Third Edition

Página 2

4 No. Operation Description Description 4 Installation and Start (4) Safety Measures  When the work is carried out with 2 or more persons, make

Página 3 - [Important]

3. PCON-CA/CFA 94 (1) PLC channel configuration (* n indicates the node address of each axis.) Parameter No. 84 PCON-CA/CFA DI (port number) PLC

Página 4

3. PCON-CA/CFA 95 (3) I/O signal assignments The signals assigned to the controller’s I/O ports vary depending on the setting of parameter No. 25.

Página 5 - Table of Contents

3. PCON-CA/CFA 96 Setting of Parameter No. 25 512-point mode Solenoid mode 1 Solenoid mode 2 3 4 5 Category Port No. Symbol Signal name Symbo

Página 6

3. PCON-CA/CFA 97 3.7.3 Position/Simple Direct Mode (Number of Occupied Channels: 4) In this mode, the actuator is operated by specifying position

Página 7 - Safety Guide

3. PCON-CA/CFA 98 1 word (channel) = 16 bitsTarget position (lower word) Target position (upper word) If the target position is a negative value, it

Página 8

3. PCON-CA/CFA 99 1 word (channel) = 16 bits Current position (lower word) Current position (upper word) Completed position number Status signal If

Página 9

3. PCON-CA/CFA 100 (3) I/O signal assignments (* In the table, ON indicates that the applicable bit is “1,” while OFF indicates that the bit is “0

Página 10

3. PCON-CA/CFA 101 (* In the table, ON indicates that the applicable bit is “1,” while OFF indicates that the bit is “0.”) Signal type Bits Symbo

Página 11

3. PCON-CA/CFA 102 3.7.4 Half Direct Mode (Number of Occupied Channels: 8) In this mode, the target position, positioning band, speed, acceleratio

Página 12

3. PCON-CA/CFA 103 (2) I/O signal assignments for each axis The I/O signals of each axis consist of eight input words (channels) and eight output

Página 13 - Alert Indication

5 No. Operation Description Description 6 Trial Operation  When the work is carried out with 2 or more persons, make it clear who is to be the

Página 14

3. PCON-CA/CFA 104 1 word (channel) = 16 bits Target position (lower word) Target position (upper word) If the target position is a negative value,

Página 15 - 1. Overview

3. PCON-CA/CFA 105 PLC input Channel (* n indicates the node address of each axis.) 1 word (ch

Página 16 - Communication

3. PCON-CA/CFA 106 (3) I/O signal assignments (* In the table, ON indicates that the applicable bit is “1,” while OFF indicates that the bit is “0

Página 17 - 2. ACON-C/CG, PCON-C/CG

3. PCON-CA/CFA 107 (* In the table, ON indicates that the applicable bit is “1,” while OFF indicates that the bit is “0.”) Signal type Bits Symbo

Página 18

3. PCON-CA/CFA 108 (* In the table, ON indicates that the applicable bit is “1,” while OFF indicates that the bit is “0.”) Signal type Bits Symbo

Página 19 - 2.2 Model Numbers

3. PCON-CA/CFA 109 3.7.5 Full Direct Mode (Number of Occupied Channels: 16) In this mode, the actuator is operated by specifying all values relati

Página 20 - 2.3 Interface Specifications

3. PCON-CA/CFA 110 (2) I/O signal assignments for each axis The I/O signals of each axis consist of sixteen input words (channels) and sixteen out

Página 21 - 2.4.1 Name of Each Part

3. PCON-CA/CFA 111 1 word (channel) = 16 bits Target position (lower word) Target position (upper word) If the target position is a negative value,

Página 22

3. PCON-CA/CFA 112 Channel (* n indicates the node address of each axis.) 1 word (channel) = 16 bi

Página 23

3. PCON-CA/CFA 113 PLC input Channel (* n indicates the node address of each axis.) 1 word (chann

Página 24

6 No. Operation Description Description 8 Maintenance and Inspection  When the work is carried out with 2 or more persons, make it clear who is

Página 25

3. PCON-CA/CFA 114 Address (* “n” shows the head register address per each axis). one word = 16 bits n+10 b15 b14 b13 b12 b11 b10 b9 b8 b7 b6 b5

Página 26

3. PCON-CA/CFA 115 (3) I/O signal assignments (* In the table, ON indicates that the applicable bit is “1,” while OFF indicates that the bit is “0

Página 27

3. PCON-CA/CFA 116 (* In the table, ON indicates that the applicable bit is “1,” while OFF indicates that the bit is “0.”) Address Bits Symbol Fun

Página 28

3. PCON-CA/CFA 117 (* In the table, ON indicates that the applicable bit is “1,” while OFF indicates that the bit is “0.”) Address Bits Symbol Fun

Página 29

3. PCON-CA/CFA 118 (* In the table, ON indicates that the applicable bit is “1,” while OFF indicates that the bit is “0.”) Signal type Bits Symbo

Página 30

3. PCON-CA/CFA 119 Signal type Bits Symbol Description Details b15 EMGS Emergency stop: An emergency stop is actuated when this signal turns ON

Página 31

3. PCON-CA/CFA 120 3.7.6 Remote I/O Mode 2 (Number of Occupied Channels: 6) In this mode, the actuator is operated by specifying position numbers,

Página 32

3. PCON-CA/CFA 121 (1) PLC channel configuration (* n indicates the node address of each axis.) Parameter No. 84 PCON-CA/CFA DI and input register

Página 33

3. PCON-CA/CFA 122 1 word (channel) = 16 bits Controller output port number Not available. Current position (lower word) Current position (upper wor

Página 34

3. PCON-CA/CFA 123 (3) I/O signal assignments For the signal assignments corresponding to each PIO pattern, refer to the I/O signal assignments fo

Página 35

7 Alert Indication The safety precautions are divided into “Danger”, “Warning”, “Caution” and “Notice” according to the warning level, as follows

Página 36

3. PCON-CA/CFA 124 3.7.7 I/O Signal Controls and Functions * ON indicates that the applicable bit signal is “1,” while OFF indicates that the bit

Página 37

3. PCON-CA/CFA 125 (5) Servo ON command (SON) [PLC output signal] Ready (SV) [PLC input signal] When the SON signal is turned ON, the servo will

Página 38

3. PCON-CA/CFA 126 (6) Home return (HOME) [PLC output signal] Home return complete (HEND) [PLC input signal] Home return in progress (GHMS) [PL

Página 39

3. PCON-CA/CFA 127 (7) Positioning start (CSTR): Used in the position/simple direct mode [PLC output signal] The CSTR command is processed at the

Página 40

3. PCON-CA/CFA 128 (10) Position complete signal (PEND) [PLC input signal] This signal turns ON after the actuator has moved to the target position

Página 41

3. PCON-CA/CFA 129 (12) Zone 1 (ZONE1) [PLC input signal] Zone 2 (ZONE2) [PLC input signal] Position zone (PZONE) [PLC input signal] Each signal

Página 42

3. PCON-CA/CFA 130 (13) +Jog (JOG+) [PLC output signal] -Jog (JOG-) [PLC output signal] These signals are used as starting commands for jog opera

Página 43

3. PCON-CA/CFA 131 (14) Jog-speed/inch-distance switching (JVEL) [PLC output signal] This signal is used to switch between the jog speed parameter

Página 44

3. PCON-CA/CFA 132 (16) Teaching command (MODE) [PLC output signal] Teaching mode signal (MODES) [PLC input signal] When the MODE signal is turne

Página 45

3. PCON-CA/CFA 133 (19) Operation mode (RMOD) [PLC output signal] Operation mode status (RMDS) [PLC input signal] The operation mode is selected

Página 47

3. PCON-CA/CFA 134 (23) Load missed in push motion (PSFL) [PLC input signal] This signal turns ON when the actuator has not contacted the load in p

Página 48

3. PCON-CA/CFA 135 (26) Load output judgment (LOAD) [PLC input signal] This signal is effective only during push-motion operation. To use the LOAD

Página 49

3. PCON-CA/CFA 136 (27) Torque level (TRQS) [PLC input signal] This signal is effective only during push-motion operation. If the motor current rea

Página 50

3. PCON-CA/CFA 137 (28) Stopping control mode (SMOD) [PLC output signal] One general characteristic of pulse motors is that their holding current a

Página 51

3. PCON-CA/CFA 138 (29) Acceleration/deceleration mode (MOD1, MOD0) [PLC output signal] These signals are used to select the acceleration/decelerat

Página 52

3. PCON-CA/CFA 139 (30) Stop Mode Selection (ASO1, ASO0) [PLC Output Signal] Select the stop mode for the duration before the movement to the next

Página 53

3. PCON-CA/CFA 140 3.8 I/O Signal Timings The maximum response time after a control signal is turned ON to operate the ROBO Cylinder in a PLC sequ

Página 54

3. PCON-CA/CFA 141 3.9 Operation This section describes the timings of basic operations in the position/simple direct mode, half direct mode and f

Página 55

3. PCON-CA/CFA 142 Set value of target position data (PLCPCON) [1] [2] [3] [4] [5][6] Specified po

Página 56

3. PCON-CA/CFA 143 (2) Operation in the half direct mode The actuator is operated by specifying the data to the target position channel, positioni

Página 57

1. Overview 9 1. Overview The open field network DeviceNet is a multi-bit, multi-vendor network for communication of both control and data signals

Página 58

3. PCON-CA/CFA 144 [1] [2] [3] [4] [5] [6] [7] [8] [9] [10][14][13][12][11] *T1: Make sure “T1 t 0 ms” is satisfied by considering the scan time of

Página 59

3. PCON-CA/CFA 145 (3) Operation in the full direct mode The actuator is operated by specifying all conditions required for positioning to channel

Página 60

3. PCON-CA/CFA 146 [1] [2] [3] [4] [5] [6] [7] [8] Set value of target position data (PLCPCON) Set value of positioning band data (PLCPCON) Set

Página 61

3. PCON-CA/CFA 147 Push-motion specification PUSH (PLCPCON) PushPositioning band *T1: Make sure “T1 t 0

Página 62

3. PCON-CA/CFA 148 Speed n2Speed n3 [1] [2][3] (4) Data change during movement In the half direct mode or full direct mode, the value currently set

Página 63

3. PCON-CA/CFA 149 3.10 DeviceNet Parameters Parameters relating to DeviceNet are Nos. 84 to 87, 90 and 159. Category: C: External interface param

Página 64

3. PCON-CA/CFA 150 z Network type (No. 87, NTYP) The network module type is specified in parameter No. 87. Do not change the default setting. z

Página 65

3. PCON-CA/CFA 151 (Example ii) Set value = “1” z indicates ON, while O indicates OFF. PCON Input register Hex

Página 66

3. PCON-CA/CFA 152 PCON Input register Hexa decimal data Output channel Hexa decimal data PCON Output register Input channel Hexa decimal data Hexa

Página 67

3. PCON-CA/CFA 153 (Example iv) Set value = “3” z indicates ON, while O indicates OFF. z FB Half Direct Mode Sp

Página 68

2. ACON-C/CG, PCON-C/CG 10 PLC PLC Flat cable Communication cable 2. ACON-C/CG, PCON-C/CG 2.1 Operation Modes and Functions ACON and PCON contro

Página 69

3. PCON-CA/CFA 154 3.11 Troubleshooting z Alarm messages, causes and remedial actions If an alarm occurs, a corresponding simple alarm code will

Página 70

3. PCON-CA/CFA 155 3.12 CE Mark If a compliance with the CE Marking is required, please follow Overseas Standards Compliance Manual (ME0287) that

Página 71

4. SCON-CA 156 PLC PLC Flat cable Communication cable 4. SCON-CA 4.1 Operation Modes and Functions SCON-CA controllers supporting DeviceNet can b

Página 72

4. SCON-CA 157 [2] Position/simple direct mode: In this mode, the actuator is operated by specifying position numbers. You can select whether to s

Página 73 - 2.8 I/O Signal Timings

4. SCON-CA 158 Communication cable Flat cable Target position: 100.00 mmPositioning band: 0.10 mmSpeed specification: 100.0 mm/sec Acceleration:

Página 74 - 2.9 Operation

4. SCON-CA 159 Flat cable Communication cable [7] Half direct mode 2: In this mode, the actuator is operated by specifying the speed, acceleration

Página 75

4. SCON-CA 160 4.2 Model Numbers The model numbers of SCON-CA controller supporting DeviceNet are indicated as follows, respectively: z SCON-CA--

Página 76

4. SCON-CA 161 4.3 Interface Specifications Item Specification DeviceNet 2.0 Group 2 only server Communication protocol Network-powered isolation

Página 77

4. SCON-CA 162 Monitor LEDs DeviceNet communication connector PCB side : MSTBA2.5/5-G-5.08AU (PHOENIX CONTACT) Cable side : SMSTB2.5/5-ST-5.08AUM

Página 78

4. SCON-CA 163 4.4.2 Monitor LED Indicators The two LEDs, MS and NS, provided on the front panel of the controller are used to check the node (con

Página 79

2. ACON-C/CG, PCON-C/CG 11 [2] Position/simple direct mode: In this mode, the actuator is operated by specifying position numbers. You can select

Página 80

4. SCON-CA 164 4.5 Selecting (Setting) the Operation Mode The operation mode is set using a parameter. Set the mode selector switch on the front

Página 81

4. SCON-CA 165 4.7 Communicating with the Master Station 4.7.1 Operation Modes and Corresponding PLC I/O Areas The channel assignments in each m

Página 82 - 2.10 DeviceNet Parameters

4. SCON-CA 166 x PLC output o SCON-CA input side (* n indicates the node address of each axis.) SCON-CA DI and input data register Position/simple

Página 83

4. SCON-CA 167 x SCON-CA output o PLC input side (* n indicates the node address of each axis.) SCON-CA DO and output data register Remote I/O mod

Página 84

4. SCON-CA 168 x SCON-CA output o PLC input side (* n indicates the node address of each axis.) SCON-CA DO and input data register Position/simple

Página 85

4. SCON-CA 169 4.7.2 Remote I/O Mode (Number of Occupied Channel: 1) In this mode, the actuator is operated by specifying position numbers just l

Página 86

4. SCON-CA 170 (1) PLC channel configuration (* n indicates the node address of each axis.) Parameter No. 84 SCON-CA DI (port number) PLC outpu

Página 87 - 2.11 Troubleshooting

4. SCON-CA 171 (3) I/O signal assignments The signals assigned to the controller’s I/O ports vary depending on the setting of parameter No. 25. (F

Página 88 - 2.12 CE Mark

4. SCON-CA 172 Setting of Parameter No. 25 512-point mode Solenoid mode 1 Solenoid mode 2 3 4 5 Category Port No. Symbol Signal name Symbol S

Página 89

4. SCON-CA 173 Setting of Parameter No. 25 Force control mode 1 Force control mode 2 6 7 Category Port No. Symbol Signal name Symbol Signal na

Página 90

2. ACON-C/CG, PCON-C/CG 12 䎳䎯䎦䎃Flat cable Communication cable [4] Full direct mode: In this mode, the actuator is operated by specifying all value

Página 91

4. SCON-CA 174 4.7.3 Position/Simple Direct Mode (Number of Occupied Channels: 4) In this mode, the actuator is operated by specifying position nu

Página 92 - 3.2 Model Numbers

4. SCON-CA 175 1 word (channel) = 16 bitsTarget position (lower word) Target position (upper word) If the target position is a negative value, it is

Página 93 - 3.3 Interface Specifications

4. SCON-CA 176 1 word (channel) = 16 bits Current position (lower word) Current position (upper word) Completed position number Status signal If th

Página 94 - 3.4.1 Name of Each Part

4. SCON-CA 177 (3) I/O signal assignments (* In the table, ON indicates that the applicable bit is “1,” while OFF indicates that the bit is “0.”)

Página 95

4. SCON-CA 178 (* In the table, ON indicates that the applicable bit is “1,” while OFF indicates that the bit is “0.”) Signal type Bits Symbol D

Página 96

4. SCON-CA 179 4.7.4 Half Direct Mode (Number of Occupied Channels: 8) In this mode, the target position, positioning band, speed, acceleration/de

Página 97

4. SCON-CA 180 (2) I/O signal assignments for each axis The I/O signals of each axis consist of eight input words (channels) and eight output word

Página 98

4. SCON-CA 181 1 word (channel) = 16 bits Target position (lower word) Target position (upper word) If the target position is a negative value, it i

Página 99

4. SCON-CA 182 PLC input Channel (* n indicates the node address of each axis.) 1 word (channel

Página 100 - 3. PCON-CA/CFA

4. SCON-CA 183 (3) I/O signal assignments (* In the table, ON indicates that the applicable bit is “1,” while OFF indicates that the bit is “0.”)

Página 101 - (3) I/O signal assignments

2. ACON-C/CG, PCON-C/CG 13 2.2 Model Numbers The model numbers of ACON and PCON controller supporting DeviceNet are indicated as follows, respecti

Página 102

4. SCON-CA 184 (* In the table, ON indicates that the applicable bit is “1,” while OFF indicates that the bit is “0.”) Signal type Bits Symbol D

Página 103

4. SCON-CA 185 (* In the table, ON indicates that the applicable bit is “1,” while OFF indicates that the bit is “0.”) Signal type Bits Symbol D

Página 104

4. SCON-CA 186 4.7.5 Full Direct Mode (Number of Occupied Channels: 16) In this mode, the actuator is operated by specifying all values relating t

Página 105

4. SCON-CA 187 (2) I/O signal assignments for each axis The I/O signals of each axis consist of sixteen input words (channels) and sixteen output

Página 106

4. SCON-CA 188 1 word (channel) = 16 bits Target position (lower word) Target position (upper word) If the target position is a negative value, it i

Página 107

4. SCON-CA 189 Channel (* n indicates the node address of each axis.) 1 word (channel) = 16 bits Zo

Página 108

4. SCON-CA 190 PLC input Channel (* n indicates the node address of each axis.) 1 word (channel) = 16 bits

Página 109

4. SCON-CA 191 6!$ 6 6 6 6 6 6% 6$ 6# 6" 6! 6 6 6 6 6#"$"$ $% %" $ !!"$&

Página 110

4. SCON-CA 192 (3) I/O signal assignments (* In the table, ON indicates that the applicable bit is “1,” while OFF indicates that the bit is “0.”)

Página 111

4. SCON-CA 193 (* In the table, ON indicates that the applicable bit is “1,” while OFF indicates that the bit is “0.”) Address Bits Symbol Functio

Página 113

2. ACON-C/CG, PCON-C/CG 14 2.3 Interface Specifications Item Specification DeviceNet 2.0 Group 2 only server Communication protocol Network-power

Página 114

4. SCON-CA 194 (* In the table, ON indicates that the applicable bit is “1,” while OFF indicates that the bit is “0.”) Address Bits Symbol Functio

Página 115

4. SCON-CA 195 (* In the table, ON indicates that the applicable bit is “1,” while OFF indicates that the bit is “0.”) Signal type Bits Symbol D

Página 116

4. SCON-CA 196 (* In the table, ON indicates that the applicable bit is “1,” while OFF indicates that the bit is “0.”) Signal type Bits Symbol D

Página 117

4. SCON-CA 197 4.7.6 Remote I/O Mode 2 (Number of Occupied Channels: 6) In this mode, the actuator is operated by specifying position numbers, jus

Página 118

4. SCON-CA 198 (1) PLC channel configuration (* n indicates the node address of each axis.) Parameter No. 84 SCON-CA DI and input register PLC out

Página 119

4. SCON-CA 199 1 word (channel) = 16 bits Controller output port number Not available. Current position (lower word) Current position (upper word) C

Página 120

4. SCON-CA 200 (3) I/O signal assignments For the signal assignments corresponding to each PIO pattern, refer to the I/O signal assignments for th

Página 121

4. SCON-CA 201 4.7.7 Position/Simple Direct Mode 2 (Number of Occupied Channels: 4) In this mode, the actuator is operated by means of force contr

Página 122 - Acceleration

4. SCON-CA 202 1 word (channel) = 16 bitsTarget position (lower word) Target position (upper word) If the target position is a negative value, it is

Página 123

4. SCON-CA 203 1 word (channel) = 16 bits Current position (lower word) Current position (upper word) Completed position number Status signal If th

Página 124

2. ACON-C/CG, PCON-C/CG 15 Status LEDs Monitor LEDs DeviceNet communication connector PCB side : MSTBA2.5/5-G-5.08AUM (PHOENIX CONTACT) Cable side

Página 125

4. SCON-CA 204 (3) I/O signal assignments (* In the table, ON indicates that the applicable bit is “1,” while OFF indicates that the bit is “0.”)

Página 126

4. SCON-CA 205 (* In the table, ON indicates that the applicable bit is “1,” while OFF indicates that the bit is “0.”) Signal type Bits Symbol D

Página 127

4. SCON-CA 206 4.7.8 Half Direct Mode (Number of Occupied Channels: 8) In this mode, the actuator is operated by means of force control (push-mot

Página 128

4. SCON-CA 207 (2) I/O signal assignments for each axis The I/O signals of each axis consist of eight input words (channels) and eight output word

Página 129

4. SCON-CA 208 1 word (channel) = 16 bits Target position (lower word) Target position (upper word) If the target position is a negative value, it i

Página 130

4. SCON-CA 209 PLC input Channel (* n indicates the node address of each axis.) 1 word (channel

Página 131

4. SCON-CA 210 (3) I/O signal assignments (* In the table, ON indicates that the applicable bit is “1,” while OFF indicates that the bit is “0.”)

Página 132

4. SCON-CA 211 (* In the table, ON indicates that the applicable bit is “1,” while OFF indicates that the bit is “0.”) Signal type Bits Symbol D

Página 133 - [PLC output signal]

4. SCON-CA 212 (* In the table, ON indicates that the applicable bit is “1,” while OFF indicates that the bit is “0.”) Signal type Bits Symbol D

Página 134

4. SCON-CA 213 4.7.9 Remote I/O Mode 3 (Number of Occupied Channels: 6) In this mode, the actuator is operated by means of force control (push-mo

Página 135

2. ACON-C/CG, PCON-C/CG 16 2.4.2 Monitor LED Indicators The two LEDs, MS and NS, provided on the front panel of the controller are used to check t

Página 136

4. SCON-CA 214 (1) PLC channel configuration (* n indicates the node address of each axis.) Parameter No. 84 SCON-CA DI and input register PLC out

Página 137

4. SCON-CA 215 1 word (channel) = 16 bits Controller output port number Not available. Current position (lower word) Current position (upper word)

Página 138

4. SCON-CA 216 (3) I/O signal assignments For the signal assignments corresponding to each PIO pattern, refer to the I/O signal assignments for th

Página 139

4. SCON-CA 217 4.7.10 Half Direct Mode 3 (Number of Occupied Channels: 8) In this operation mode, the jog function available in the half numerica

Página 140

4. SCON-CA 218 (2) I/O signal assignments for each axis The I/O signals of each axis consist of eight input words (channels) and eight output word

Página 141

4. SCON-CA 219 MOD1 MOD0 Target position (lower word) Target position (upper word) If the target position is a negative value, it is indicated by a

Página 142

4. SCON-CA 220 PLC input Channel (* n indicates the node address of each axis.) 1 word (chann

Página 143

4. SCON-CA 221 (3) I/O signal assignments (* In the table, ON indicates that the applicable bit is “1,” while OFF indicates that the bit is “0.”)

Página 144

4. SCON-CA 222 (* In the table, ON indicates that the applicable bit is “1,” while OFF indicates that the applicable bit is “0.”) Signal type Bit

Página 145

4. SCON-CA 223 (* In the table, ON indicates that the applicable bit is “1,” while OFF indicates that the applicable bit is “0.”) Signal type Bit

Página 146 - 3.8 I/O Signal Timings

2. ACON-C/CG, PCON-C/CG 17 2.5 Selecting (Setting) the Operation Mode The operation mode is set using a parameter. Set the mode selector switch o

Página 147 - 3.9 Operation

4. SCON-CA 224 4.7.11 I/O Signal Controls and Functions * ON indicates that the applicable bit signal is “1,” while OFF indicates that the bit si

Página 148 - (PLCPCON)

4. SCON-CA 225 (5) Servo ON command (SON) [PLC output signal] Ready (SV) [PLC input signal] When the SON signal is turned ON, the servo will tur

Página 149

4. SCON-CA 226 (6) Home return (HOME) [PLC output signal] Home return complete (HEND) [PLC input signal] Home return in progress (GHMS) [PLC in

Página 150

4. SCON-CA 227 (7) Positioning start (CSTR): Used in the position/simple direct mode 1,2 [PLC output signal] The CSTR command is processed at the

Página 151

4. SCON-CA 228 (10) Position complete signal (PEND) [PLC input signal] This signal turns ON after the actuator has moved to the target position and

Página 152

4. SCON-CA 229 (12) Zone 1 (ZONE1) [PLC input signal] Zone 2 (ZONE2) [PLC input signal] Position zone (PZONE) [PLC input signal] Each signal tur

Página 153

4. SCON-CA 230 (13) +Jog (JOG+) [PLC output signal] -Jog (JOG-) [PLC output signal] These signals are used as starting commands for jog operation

Página 154 - Caution

4. SCON-CA 231 (14) Jog-speed/inch-distance switching (JVEL) [PLC output signal] This signal is used to switch between the jog speed parameter when

Página 155 - 3.10 DeviceNet Parameters

4. SCON-CA 232 (16) Teaching command (MODE) [PLC output signal] Teaching mode signal (MODES) [PLC input signal] When the MODE signal is turned ON

Página 156

4. SCON-CA 233 (19) Operation mode (RMOD) [PLC output signal] Operation mode status (RMDS) [PLC input signal] The operation mode is selected as s

Página 157

2. ACON-C/CG, PCON-C/CG 18 2.7 Communicating with the Master Station 2.7.1 Operation Modes and Corresponding PLC I/O Areas The channel assignmen

Página 158

4. SCON-CA 234 (23) Load missed in push motion (PSFL) [PLC input signal] This signal turns ON when the actuator has not contacted the load in push-

Página 159

4. SCON-CA 235 (26) Load output judgment (LOAD) [PLC input signal] This signal is effective only during push-motion operation. To use the LOAD si

Página 160 - 3.11 Troubleshooting

4. SCON-CA 236 (27) Torque level (TRQS) [PLC input signal] This signal is effective only during push-motion operation. If the motor current reach

Página 161 - 3.12 CE Mark

4. SCON-CA 237 (28) Absolute Battery Voltage Low Warning (BALM) PLC Input Signal With an absolute system, this signal is OFF when the absolute b

Página 162 - 4. SCON-CA

4. SCON-CA 238 (30) Acceleration/deceleration mode (MOD1, MOD0) [PLC output signal] These signals are used to select the acceleration/deceleration

Página 163

4. SCON-CA 239 (31) Standstill Mode Selection (ASO0, ASO1) PLC Output Signals Select the stop mode to be applied while the actuator is standing

Página 164

4. SCON-CA 240 *1 If the CLBR is turned OFF during this period, the signal is not recognized and therefore calibration is not perfor

Página 165

4. SCON-CA 241 4.8 I/O Signal Timings The maximum response time after a given control signal is turned ON to operate the ROBO Cylinder using the P

Página 166 - 4.2 Model Numbers

4. SCON-CA 242 4.9 Operation Next, timings in the position/simple direct mode 1, 2, half direct mode 1 to 3 and full direct mode are explained usi

Página 167 - 4.3 Interface Specifications

4. SCON-CA 243 [1] [2] Set value of target position data Specified position number Positioni

Página 168 - 4.4.1 Name of Each Part

2. ACON-C/CG, PCON-C/CG 19 x ACON or PCON output o PLC input side (* n indicates the node address of each axis.) ACON or PCON DO and output data

Página 169

4. SCON-CA 244 (2) Operation in the half direct mode 1 to 3 Operate the actuator by specifying data for the PLC’s target position, positioning ban

Página 170

4. SCON-CA 245 Set value of target position data [1] [2] [3] [4] [5] [6] [7] [8] [9] [10][14

Página 171 - Push-motion

4. SCON-CA 246 (3) Operation in the full direct mode Operate the actuator by specifying from the PLC all conditions required for positioning, such

Página 172

4. SCON-CA 247 Set value of target position data [1] [2] Set value of positioning band data Set value o

Página 173

4. SCON-CA 248 [9] [10] Positioning band Push specification Push direction specification Positioning command

Página 174

4. SCON-CA 249 (4) Data change during movement In the half direct mode 1 to 3 and full direct mode, the values of target position data, accelerati

Página 175

4. SCON-CA 250 4.10 DeviceNet Parameters The parameters relating to DeviceNet are parameter Nos. 84 to 87, 90 and 159. Category: C: External inter

Página 176

4. SCON-CA 251 z Network type (No. 87 NTYP) Specify the network module in parameter No. 87. Do not change the default value. z Fieldbus I/O form

Página 177

4. SCON-CA 252 (Example ii) Set value = “1” z indicates ON, while O indicates OFF. SCON input register Hexade

Página 178

4. SCON-CA 253 (Example iii) Set value = “2” z indicates ON, while O indicates OFF. SCON input register Hexad

Página 179

2. ACON-C/CG, PCON-C/CG 20 2.7.2 Remote I/O Mode (Number of Occupied Channel: 1) In this mode, the actuator is operated by specifying position num

Página 180

4. SCON-CA 254 (Example iv) Set value = “3” z indicates ON, while O indicates OFF. z FB Half Direct Mode Spee

Página 181

4. SCON-CA 255 4.11 Troubleshooting z Alarm messages, causes and remedial actions If an alarm occurs, a corresponding simple alarm code will be i

Página 182

5. Troubleshooting 256 5. Troubleshooting If you encountered a problem concerning DeviceNet, check the operating condition using the table below a

Página 183

6. Change History 257 6. Change History Revision Date Description of Revision November 2011 June 2012 November 2012 First edition C

Página 186

Manual No.: ME0256-3B (November 2012)The information contained in this document is subject to change without notice for purposes ofproduct improvem

Página 187

2. ACON-C/CG, PCON-C/CG 21 (1) PLC channel configuration (* n indicates the node address of each axis.) Parameter No. 84 ACON or PCON DI (port nu

Página 188

2. ACON-C/CG, PCON-C/CG 22 (3) I/O signal assignments The signals assigned to the controller’s I/O ports vary depending on the setting of paramete

Página 189

2. ACON-C/CG, PCON-C/CG 23 Setting of Parameter No. 25 512-point mode Solenoid mode 1 Solenoid mode 2 3 4 5 Category Port No. Symbol Signal

Página 190

Please Read Before Use Thank you for purchasing our product. This Operation Manual explains the handling methods, structure and maintenance of

Página 191

2. ACON-C/CG, PCON-C/CG 24 Setting of Parameter No. 25 Positioning mode (standard) Teaching mode (teaching type) 256-point mode (256-point type)

Página 192

2. ACON-C/CG, PCON-C/CG 25 Setting of Parameter No. 25 512-point mode Solenoid mode 1 Solenoid mode 2 3 4 5 Category Port No. Symbol Signal

Página 193

2. ACON-C/CG, PCON-C/CG 26 2.7.3 Position/Simple Direct Mode (Number of Occupied Channels: 4) In this mode, the actuator is operated by specifying

Página 194

2. ACON-C/CG, PCON-C/CG 27 1 word (channel) = 16 bitsTarget position (lower word) Target position (upper word) If the target position is a negative

Página 195

2. ACON-C/CG, PCON-C/CG 28 1 word (channel) = 16 bits Current position (lower word) Current position (upper word) Completed position number Status

Página 196

2. ACON-C/CG, PCON-C/CG 29 (3) I/O signal assignments (* In the table, ON indicates that the applicable bit is “1,” while OFF indicates that the b

Página 197

2. ACON-C/CG, PCON-C/CG 30 (* In the table, ON indicates that the applicable bit is “1,” while OFF indicates that the bit is “0.”) Signal type Bit

Página 198

2. ACON-C/CG, PCON-C/CG 31 2.7.4 Half Direct Mode (Number of Occupied Channels: 8) In this mode, the target position, positioning band, speed, acc

Página 199 - Deceleration

2. ACON-C/CG, PCON-C/CG 32 (2) I/O signal assignments for each axis The I/O signals of each axis consist of eight input words (channels) and eight

Página 200

2. ACON-C/CG, PCON-C/CG 33 1 word (channel) = 16 bits Target position (lower word) Target position (upper word) If the target position is a negative

Página 201

Caution: The following functions are described in the separate operation manual. Title of operation manual/Overview Control number 1 Device

Página 202

2. ACON-C/CG, PCON-C/CG 34 PLC input Channel (* n indicates the node address of each axis.) 1

Página 203

2. ACON-C/CG, PCON-C/CG 35 (3) I/O signal assignments (* In the table, ON indicates that the applicable bit is “1,” while OFF indicates that the b

Página 204

2. ACON-C/CG, PCON-C/CG 36 (* In the table, ON indicates that the applicable bit is “1,” while OFF indicates that the bit is “0.”) Signal type Bit

Página 205

2. ACON-C/CG, PCON-C/CG 37 (* In the table, ON indicates that the applicable bit is “1,” while OFF indicates that the bit is “0.”) Signal type Bit

Página 206

2. ACON-C/CG, PCON-C/CG 38 2.7.5 Full Direct Mode (Number of Occupied Channels: 16) In this mode, the actuator is operated by specifying all value

Página 207

2. ACON-C/CG, PCON-C/CG 39 (2) I/O signal assignments for each axis The I/O signals of each axis consist of sixteen input words (channels) and six

Página 208

2. ACON-C/CG, PCON-C/CG 40 1 word (channel) = 16 bits Target position (lower word) Target position (upper word) If the target position is a negative

Página 209

2. ACON-C/CG, PCON-C/CG 41 Channel (* n indicates the node address of each axis.) (*1) Signal ass

Página 210

2. ACON-C/CG, PCON-C/CG 42 PLC input Channel (* n indicates the node address of each axis.) (

Página 211

2. ACON-C/CG, PCON-C/CG 43 (3) I/O signal assignments (* In the table, ON indicates that the applicable bit is “1,” while OFF indicates that the b

Página 212

Table of Contents Safety Guide...

Página 213

2. ACON-C/CG, PCON-C/CG 44 (* In the table, ON indicates that the applicable bit is “1,” while OFF indicates that the bit is “0.”) Address Bits Sym

Página 214

2. ACON-C/CG, PCON-C/CG 45 (* In the table, ON indicates that the applicable bit is “1,” while OFF indicates that the bit is “0.”) Address Bits Sym

Página 215

2. ACON-C/CG, PCON-C/CG 46 (* In the table, ON indicates that the applicable bit is “1,” while OFF indicates that the bit is “0.”) Signal type Bit

Página 216

2. ACON-C/CG, PCON-C/CG 47 2.7.6 Remote I/O Mode 2 (Number of Occupied Channels: 6) In this mode, the actuator is operated by specifying position

Página 217

2. ACON-C/CG, PCON-C/CG 48 (1) PLC channel configuration (* n indicates the node address of each axis.) Parameter No. 84 ACON or PCON DI and input

Página 218

2. ACON-C/CG, PCON-C/CG 49 1 word (channel) = 16 bits Controller output port number Not available. Current position (lower word) Current position (u

Página 219

2. ACON-C/CG, PCON-C/CG 50 (3) I/O signal assignments For the signal assignments corresponding to each PIO pattern, refer to the I/O signal assign

Página 220

2. ACON-C/CG, PCON-C/CG 51 2.7.7 I/O Signal Controls and Functions * ON indicates that the applicable bit signal is “1,” while OFF indicates that

Página 221

2. ACON-C/CG, PCON-C/CG 52 (5) Servo ON command (SON) [PLC output signal] Ready (SV) [PLC input signal] When the SON signal is turned ON, the se

Página 222

2. ACON-C/CG, PCON-C/CG 53 (6) Home return (HOME) [PLC output signal] Home return complete (HEND) [PLC input signal] Home return in progress (GH

Página 223

3.7 Communicating with the Master Station ... 91 3.7.1 Operat

Página 224

2. ACON-C/CG, PCON-C/CG 54 (7) Positioning start (CSTR): Used in the position/simple direct mode [PLC output signal] The CSTR command is processed

Página 225

2. ACON-C/CG, PCON-C/CG 55 (10) Position complete signal (PEND) [PLC input signal] This signal turns ON after the actuator has moved to the target

Página 226

2. ACON-C/CG, PCON-C/CG 56 (12) Zone 1 (ZONE1) [PLC input signal] Zone 2 (ZONE2) [PLC input signal] Position zone (PZONE) [PLC input signal] Eac

Página 227

2. ACON-C/CG, PCON-C/CG 57 (13) +Jog (JOG+) [PLC output signal] -Jog (JOG-) [PLC output signal] These signals are used as starting commands for j

Página 228

2. ACON-C/CG, PCON-C/CG 58 (14) Jog-speed/inch-distance switching (JVEL) [PLC output signal] This signal is used to switch between the jog speed pa

Página 229

2. ACON-C/CG, PCON-C/CG 59 (16) Teaching command (MODE) [PLC output signal] Teaching mode signal (MODES) [PLC input signal] When the MODE signal

Página 230

2. ACON-C/CG, PCON-C/CG 60 (19) Operation mode (RMOD) [PLC output signal] Operation mode status (RMDS) [PLC input signal] The operation mode is s

Página 231

2. ACON-C/CG, PCON-C/CG 61 (23) Load missed in push motion (PSFL) [PLC input signal] This signal turns ON when the actuator has not contacted the l

Página 232

2. ACON-C/CG, PCON-C/CG 62 (26) Load output judgment (LOAD) [PLC input signal] [Dedicated PCON function] This signal is effective only during push-

Página 233

2. ACON-C/CG, PCON-C/CG 63 (27) Torque level (TRQS) [PLC input signal] [Dedicated PCON function] This signal is effective only during push-motion o

Página 234

1 Safety Guide “Safety Guide” has been written to use the machine safely and so prevent personal injury or property damage beforehand. Make sure t

Página 235

2. ACON-C/CG, PCON-C/CG 64 (28) Stopping control mode (SMOD) [PLC output signal] [Dedicated PCON function] One general characteristic of pulse moto

Página 236

2. ACON-C/CG, PCON-C/CG 65 (29) Acceleration/deceleration mode (MOD1, MOD0) [PLC output signal] [Dedicated ACON function] These signals are used

Página 237

2. ACON-C/CG, PCON-C/CG 66 (30) Stop Mode Selection (ASO1, ASO0) [PLC Output Signal] Select the stop mode for the duration before the movement to t

Página 238

2. ACON-C/CG, PCON-C/CG 67 2.8 I/O Signal Timings The maximum response time after a control signal is turned ON to operate the ROBO Cylinder in a

Página 239

2. ACON-C/CG, PCON-C/CG 68 2.9 Operation This section describes the timings of basic operations in the position/simple direct mode, half direct mo

Página 240

2. ACON-C/CG, PCON-C/CG 69 Set value of target position data [1] [2] [3] [4] [5][6] Specified posit

Página 241

2. ACON-C/CG, PCON-C/CG 70 (2) Operation in the half direct mode The actuator is operated by specifying the data to the target position channel, p

Página 242

2. ACON-C/CG, PCON-C/CG 71 [1] [2] [3] [4] [5] [6] [7] [8] [9] [10][14][13][12][11] *T1: Make sure “T1 t 0 ms” is satisfied by considering the scan

Página 243

2. ACON-C/CG, PCON-C/CG 72 (3) Operation in the full direct mode The actuator is operated by specifying all conditions required for positioning to

Página 244

2. ACON-C/CG, PCON-C/CG 73 Set value of target position data Set value of positioning band data Set value of speed data Set value of push-motion cur

Página 245 - Target position

2 No. Operation Description Description 2 Transportation  When carrying a heavy object, do the work with two or more persons or utilize equipm

Página 246

2. ACON-C/CG, PCON-C/CG 74 Current position Moving Push-motion specification Push direction specificatio

Página 247 - 4.8 I/O Signal Timings

2. ACON-C/CG, PCON-C/CG 75 Set value of speed or acceleration/deceleration Actuator speed Speed n2Speed n3 [1] [2][3] (4) Data change during moveme

Página 248 - 4.9 Operation

2. ACON-C/CG, PCON-C/CG 76 2.10 DeviceNet Parameters Parameters relating to DeviceNet are Nos. 84 to 87 and 90. Category: C: External interface pa

Página 249

2. ACON-C/CG, PCON-C/CG 77 z Network type (No. 87, NTYP) The network module type is specified in parameter No. 87. Do not change the default setti

Página 250

2. ACON-C/CG, PCON-C/CG 78 (Example ii) Set value = “1” z indicates ON, while O indicates OFF. Input register

Página 251

2. ACON-C/CG, PCON-C/CG 79 Input register Hexa decimal data Output channel Hexa decimal data Output register Input channel Hexa decimal data Hexa d

Página 252

2. ACON-C/CG, PCON-C/CG 80 (Example iv) Set value = “3” z indicates ON, while O indicates OFF. Input register H

Página 253

2. ACON-C/CG, PCON-C/CG 81 2.11 Troubleshooting z Alarm messages, causes and remedial actions If an alarm occurs, a corresponding simple alarm co

Página 254

2. ACON-C/CG, PCON-C/CG 82 2.12 CE Mark If a compliance with the CE Marking is required, please follow Overseas Standards Compliance Manual (ME028

Página 255

3. PCON-CA/CFA 83 PLC PLC Flat cable Communication cable 3. PCON-CA/CFA 3.1 Operation Modes and Functions PCON-CA/CFA controllers supporting Dev

Página 256 - 4.10 DeviceNet Parameters

3 No. Operation Description Description (2) Cable Wiring  Use our company’s genuine cables for connecting between the actuator and controller, a

Página 257

3. PCON-CA/CFA 84 [2] Position/simple direct mode: In this mode, the actuator is operated by specifying position numbers. You can select whether t

Página 258

3. PCON-CA/CFA 85 䎳䎯䎦䎃PLC PLCFlat cable Communication cable [4] Full direct mode: In this mode, the actuator is operated by specifying all values

Página 259

3. PCON-CA/CFA 86 3.2 Model Numbers The model numbers of PCON-CA/CFA controller supporting DeviceNet are indicated as follows, respectively: z PC

Página 260

3. PCON-CA/CFA 87 3.3 Interface Specifications Item Specification DeviceNet 2.0 Group 2 only server Communication protocol Network-powered isolati

Página 261 - 4.11 Troubleshooting

3. PCON-CA/CFA 88 3.4 DeviceNet Interface 3.4.1 Name of Each Part The name of each part relating to DeviceNet is shown.

Página 262 - 5. Troubleshooting

3. PCON-CA/CFA 89 3.4.2 Monitor LED Indicators The two LEDs, MS and NS, provided on the front panel of the controller are used to check the node (

Página 263 - 6. Change History

3. PCON-CA/CFA 90 3.5 Selecting (Setting) the Operation Mode The operation mode is set using a parameter. Set the mode selector switch on the fro

Página 264

3. PCON-CA/CFA 91 3.7 Communicating with the Master Station 3.7.1 Operation Modes and Corresponding PLC I/O Areas The channel assignments in eac

Página 265

3. PCON-CA/CFA 92 x PCON-CA/CFA output o PLC input side (* n indicates the node address of each axis.) PCON-CA/CFA DO and output data register Rem

Página 266 - 12.11.000

3. PCON-CA/CFA 93 3.7.2 Remote I/O Mode (Number of Occupied Channel: 1) In this mode, the actuator is operated by specifying position numbers, jus