3. ACON-C/CG, PCON-C/CG
CC-Link
12
2) Position/Simplified Direct Value Mode : This is the operation method with the position No. set up.
Whether if setup the target position using a value directly by means
of the change over of the control signal, or using the value
registered on the position data, can be selected.
For “Speed”, “Acceleration/Deceleration” and “Positioning Width”,
use the values already registered on the position data. The settable
No. of position data items is max 768 points.
No. of Occupied Stations: One Station
3) Half Direct Value Mode : This is the operation method with the “Speed”, “Acceleration/Deceleration”,
“Pressing Current Value” set up directly using the numerical values, in addition to
the “Target Position”.
No. of Occupied Stations: Two Stations
Target Position: 100.00 mm
Position No. 0
ACON or PCON
applicable to CC-Link
Actuator
Deceleration
Speed
Acceleration Pressing
ACON or PCON
applicable to CC-Link
Actuator
Target Position: 100.00mm
Positioning Width: 0.10mm
Speed Setup: 100.0mm/s
Acceleration/Deceleration: 0.30G
Pressing Current Value: 50%