4. SCON-CA
196
(* In the table, ON indicates that the applicable bit is “1,” while OFF indicates that the bit is “0.”)
Signal type Bits Symbol Description Details
b15 EMGS
Emergency stop: An emergency stop is being executed when
the signal is ON.
4.7.11 (2)
b14 PWR
Controller ready: The signal turns ON when the controller
becomes ready.
4.7.11 (1)
b13 ZONE2
Zone 2: The signal is ON when the current position is inside the
specified zone.
4.7.11 (12)
b12 ZONE1
Zone 1: The signal is ON when the current position is inside the
specified zone.
4.7.11 (12)
b11 PZONE
Position zone: The signal is ON when the current position is
inside the specified position zone.
4.7.11 (12)
b10 MODES
Teaching mode signal: The signal is ON when the teaching
mode is selected.
4.7.11 (26)
b9 WEND
Position data read complete: The signal turns ON when the
position data read is complete.
4.7.11 (27)
b8 RMDS
Operation mode: The signal is OFF when the current mode
AUTO, or ON when the current mode is MANU.
4.7.11 (19)
b7 BALM
Absolute battery voltage low warning: This signal turns ON when
the voltage drops.
4.7.11 (6)
b6 - Not available 4.7.11 (25)
b5 PSFL
Missed load during push-motion operation: The signal turns ON
when the actuator missed the load during push-motion
operation.
4.7.11 (23)
b4 SV Ready: The signal is ON when the servo is ON. 4.7.11 (5)
b3 ALM Alarm: The signal turns ON when an alarm occurs. 4.7.11 (3)
b2 MOVE Moving signal: The signal is ON while the actuator is moving. 4.7.11 (9)
b1 HEND
Home return complete: The signal turns ON when the home
return is completed.
4.7.11 (6)
PLC input
Status
signal 2
b0 PEND
Positioning complete signal: The signal turns ON when the
positioning is completed.
4.7.11 (10)